ACS Technology
Providing 
Pathogen Control and
Extend Shelf-Life
with 
"ACS"
Acidic Calcium Sulfate
" USDA & FDA Approved " 
 
 

 

 

 

 

 

 

 

 

Your Subtitle text

"pHixr 100" pH Reducer / Water Treatment

WHAT IS pHixr 100®?

                Acidified Calcium Sulfate

            pH Reducer -
water acidifier.

FDA/USDA Approved

GRAS (Generally Regarded As Safe)

For use in various applications, such as: pools, ponds, animal drinking water, food processing water;

Manufactured under the technology patents


BENEFITS OF pHixr 100®  

Effective at all water temperatures.

Human food grade. GRAS - FDA Approved

Effective in fresh or red water.

No fumes or odors.

Ready-to-use. No mixing required.

Buffered - Safer Alternative that other harsh acids, such as Muriatic & Hydrochloric Acids


MONEY SAVING FEATURES OF pHixr 100®

The key to effective chlorine use is to keep it in the form of HOCl (hypochlorous acid). This is accomplished by controlling the pH of the water.

Managing the pH and effectively utilizing the chlorine can be accomplished cost-effectively through the use of pHixr®.

*Amount of pHixr required to adjust water pH may vary by location depending upon water quality (pH and dissolved chemicals such as minerals, bicarbonates, etc.)

 

For further information on Applications of our

“ Acidic Calcium Sulfate Based Products “

please call 719-265-9141

or email to
Applications@ACSProductInfo.com
or
 Click Here to check out our other "ACS" Products on our main web site
 

please contact us for a PDF file MSDS

applications@acsproductinfo.com

or at

ACSProductInfo.com

or call

719-265-9141

 



 

 

 

 

 

 

 

 

 

 



Click Here

For further information on other Applications

of our
 
“ Acidic Calcium Sulfate Based Products “


also

please contact us for a PDF file MSDS


applications@acsproductinfo.com


or at

ACSProductInfo.com

or call

719-265-9141


pHixr 100 pH Reducer / Acidifier / Water Conditioner

 

MATERIAL SAFETY DATA SHEET

 

Section 1 – PRODUCT / MANUFACTURE’S IDENTIFICATION

 

PRODUCT NAME      pHixr I00  pH Reducer / Acidifier / Water conditioner          EMERGENCY NUMBER             800-424-9300         

3

HEALTH

HAZARD RATING

 

4=EXTREME

3=HIGH

2=MODERATE

1=SLIGHT

0=INSIGNIFICANT

0

FIRE

2

REACTIVITY

C

MINIMUM PERSONAL PROTECTION

A=GOGGLES  B=GOGGLES & GLOVES

C=GOGGLES, GLOVES, & APRON

 

MSDS NUMBER       14076-H                   PRODUCT USE                         Acidulant                

 

VERSION NUMBER   1.0                           DOT HAZARD CLASS                                8             

 

ISSUE DATE:            09/04/07                 DOT SHIPPING NAME:             Corrosive liquid, Acidic,

                                                                                                                Inorganic, N.O.S.

 

REVISION DATE:       09/09/07                 UN NUMBER                            3264

 

PREPARED BY:        ACS Technology       PACKAGING GROUP                                II

 

MANUFACTURER     Hydrite Chemical Co for

ACS Technology

                                5470 Wilson Rd.

                                COS, CO 8099

                                719-265-9141

 

ABBREVIATION KEY: NA= Not Applicable   NE = Not Established   ND = Not Determined

Section 2 – HAZARDOUS INGREDIENTS INFORMATION

 

CHEMICAL INDENTITY                                    HAZARDOUS                                      CAS REG#                                    PERCENTAGES

 

Acidic Calcium Sulfate                                         Yes                                                   NA                                                40 – 60

 

Water                                                                    No                                              7732-18-5                                          40 – 60

 

 

Section 3 – PHYSICAL DATA

 

BOILING POINT: – 104ºC – 105ºC                        SPECIFIC GRAVITY: – (H2O = 1.0) – 1. 28 - 1.30           ODOR: – Odorless and slightly acidic

 

PHYSICAL STATE: - Liquid                                   Appearance – clear to slightly cloudy or opaque       pH: - <1.0

 

FREEZING POINT:  - 5ºC

 

Section 4 – HEALTH HAZARD DATA

 

Exposure to significant quantities of liquid and/or mist may cause irritation or burns to body tissue. Swallowing of large quantities may be fatal.  Harmful if undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner is inhaled.  Excessive heat (>100OC)  may cause volatility.  Slightly water reactive.  Contains strong inorganic acid. 

 

POTENTIAL HEALTH EFFECTS

 

Inhalation:  Inhalation of undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner may produces damaging effects on the mucous membranes and upper respiratory tract. Symptoms may include irritation of the nose and throat.  May cause lung edema, a medical emergency.

 

Skin Contact: Corrosive. Symptoms of redness, pain, and burn can occur by skin contact with undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner.

 

Ingestion: pHixr I00 pH Reducer / Acidifier / Water conditioner is a food additive, however ingestion of undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner may cause burns to the mouth, throat, and stomach.

 

Eye Contact: Contact with undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner may cause blurred vision, redness, pain & severe tissue burns. 

 

Aggravation of Pre-existing Conditions: Persons with pre-existing skin disorders or eye problems or impaired respiratory function may be more susceptible to the effects of undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner.

 

Section 5 – FIRST AID MEASURES

 

Inhalation:  Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention immediately.

 

Skin Contact: In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes.  Wash clothing before reuse.

 

Ingestion: If swallowed, DO NOT INDUCE VOMITNG. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

 

Eye Contact: Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.

 

Section 6 – FIRE FIGHTING MEASURES

 

Fire: Concentrated material is a strong dehydrating agent. Do not store around unapproved chemicals (see Section 10). 

 

Explosion: A mild exothermic reaction may occur when undiluted pHixr I00 is added to water. 

 

ACS TECHNOLOGY                       Page I of 3  MSDS I4076-H – pHixr I00 pH Reducer / Acidifier / Water Conditioner

Fire Extinguishing Media: Dry chemical, foam or carbon dioxide.  Water spray may be used to keep fire exposed containers cool.

 

Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. Structural firefighter's clothing is ineffective for fires involving this material. Stay away from sealed containers.

 

Section 7 – ACCIDENTAL RELEASE MEASURES

 

 

Ventilate area of leak or spill. Wear appropriate personal protective equipment. Isolate hazard area. Keep unnecessary and unprotected personnel from entering. Contain and recover liquid when possible. Neutralize with alkaline material (soda ash, lime), then absorb with an inert material (e.g., vermiculite, dry sand, earth), and place in a chemical waste container. Do not use combustible materials, such as saw dust. Do not flush to sewer. US regulations (CERCLA) require reporting spills and releases to soil, water, and air in excess of reportable quantities. The toll free number for the US Coast Guard National Response Center is 800-424-8802.

 

Section 8 – HANDLING AND STORAGE

 

Store  in well ventilated storage area.  Protect from physical damage. Keep  away from incompatible materials. When diluting, always add pHixr I00 pH Reducer / Acidifier / Water conditioner to water; never add water to undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner.  

 

Section 9 – EXPOSURE CONTROLS / PERSONAL PROTECTION

 

Airborne Exposure Limits:

For  undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner.

-OSHA Permissible Exposure Unit (PEL): 1mg/m3 (TWA)

-ACGIH Threshold Unit Value (TLV): 1 mg/m3 (TWA), 3 mg/m3 (STEL),  A2 - suspected human carcinogen for undiluted pHixr I00 contained in strong inorganic acid mists.

 

Skin Protection: Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.

 

Eye Protection: Use chemical safety goggles and/or a full face shield where splashing is possible. Maintain eye wash fountain and quick-drench

facilities in work area.

 

Section 10 – STABILITY AND REACTIVITY

 

Stability: Stable under ordinary conditions of use and storage.

 

Hazardous Decomposition Products: Reacts with carbonates to generate carbon dioxide gas, and with cyanides and sulfides to form poisonous hydrogen cyanide and hydrogen sulfide respectively.

 

Hazardous Polymerization: Will not occur.

 

Incompatibilities: Potassium chlorate, potassium perchlorate, potassium permanganate, sodium, lithium, bases, organic material, halogens, metal acetyl ides, oxides and hydrides, metals (yields hydrogen gas), strong oxidizing and reducing agents and many other reactive substances.

 

Conditions to Avoid:  Excessive Heat (>100OC) and incompatibles.

 

Section 11 – TOXICOLOGICAL INFORMATION

 

Toxicological Data: Oral rat LD50: 2140 mg/kg; inhalation rat LC50: 510 mg/m3/2H; standard Draize, eye rabbit, 250 µg (severe); investigated as a tumorigen, mutagen, reproductive effector (0.1N solution).

 

Carcinogenicity: Cancer Status: The International Agency for Research on Cancer (IARC) has classified "strong inorganic acid mists" as a known human carcinogen, (IARC category 1).

 

Section 12 – ECOLOGICAL INFORMATION

 

Environmental Fate: When released into the soil, this undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner may leach into groundwater. When released into the air, this material may be removed from the atmosphere to a moderate extent by wet deposition. When released into the air, this material may be removed from the atmosphere to a moderate extent by dry deposition.

Environmental Toxicity: This undiluted pHixr I00 pH Reducer / Acidifier / Water conditioner may be toxic to aquatic life.

 

Section 13 – DISPOSAL CONSIDERATIONS

 

Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3. Additionally, waste generators must consult state and local hazardous waste regulations to ensure complete and accurate classification.

RCRA P-Series: None listed.

RCRA U-Series: None listed.

 

Section 14 – TRANSPORTATION

 

Shipping Name:                      Corrosive liquid, Acidic, Inorganic, N.O.S (ACIDIC CALCIUM SULFATE) pHixr I00 pH Reducer / Acidifier / Water conditioner

Hazard Class:                          8

UN Number:                            UN3264

Packing Group:                      II

 

ACS TECHNOLOGY                   Page 2 of 3    MSDS I4076-H – pHixr I00 pH Reducer / Acidifier / Water Conditioner

Section 15 – REGULATORY INFORMATION

 

TSCA

CAS# 7664-93-9 is listed on the TSCA inventory.

Health & Safety Reporting List

None of the chemicals in pHixr I00 pH Reducer / Acidifier / Water conditioner are on the Health & Safety Reporting List.

Chemical Test Rules

None of the chemicals in pHixr I00 pH Reducer / Acidifier / Water conditioner are under a Chemical Test Rule.

Section 12b

None of the chemicals in pHixr I00 pH Reducer / Acidifier / Water conditioner are listed under TSCA Section 12b.

TSCA Significant New Use Rule

None of the chemicals in this material, pHixr I00 pH Reducer / Acidifier / Water conditioner, have a SNUR under TSCA.

 

SARA

Section 313

pHixr I00 pH Reducer / Acidifier / Water conditioner may contain sulfuric acid (CAS# 7664-93-9, 95 98 0%), which is subject to the reporting requirements of Section 313 of SARA Title III and 40 CFR Part 373.

Clean Air Act:

This material does not contain any hazardous air pollutants. This material does not contain any Class 1 Ozone depletors. This material does not contain any Class 2 Ozone depletors.

Clean Water Act:

CAS# 7664-93-9 is listed as a Hazardous Substance under the CWA. None of the chemicals in this product are listed as Priority Pollutants under the CWA. None of the chemicals in this product are listed as Toxic Pollutants under the CWA.

OSHA:

None of the chemicals in pHixr I00 pH Reducer / Acidifier / Water conditioner are considered highly hazardous by OSHA.

STATE

CAS# 7664-93-9 can be found on the following state right to know lists: California, New Jersey, Florida, Pennsylvania, Minnesota, and Massachusetts.

California No Significant Risk Level: None of the chemicals in this product are listed. European/International Regulations

European Labeling in Accordance with EC Directives

Hazard Symbols: C

 

Section 16 – ADDITIONAL INFORMATION

 

MSDS Creation Date: 6/20/2005

Revision #3 Date: 6/20/2006

The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall ACS Technology be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if ASC Technology has been advised of the possibility of such damages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACS TECHNOLOGY          Page 3 of 3  MSDS I4076-H – pHixr I00 pH Reducer / Acidifier / Water Conditioner


MATERIAL SAFETY DATA SHEET

USDA approved "ACS / pHixr 100" for Salmonella Control Treatment in Processing Water
 

Section 1 – PRODUCT / MANUFACTURE’S IDENTIFICATION

 

PRODUCT NAME      pHixr I00                           EMERGENCY NUMBER             800-424-9300         

3

HEALTH

HAZARD RATING

 

4=EXTREME

3=HIGH

2=MODERATE

1=SLIGHT

0=INSIGNIFICANT

0

FIRE

2

REACTIVITY

C

MINIMUM PERSONAL PROTECTION

A=GOGGLES  B=GOGGLES & GLOVES

C=GOGGLES, GLOVES, & APRON

 

MSDS NUMBER       14076-H                   PRODUCT USE                         Acidulant                

 

VERSION NUMBER   1.0                           DOT HAZARD CLASS                                8             

 

ISSUE DATE:            09/04/07                 DOT SHIPPING NAME:             Corrosive liquid, Acidic,

                                                                                                                Inorganic, N.O.S.

 

REVISION DATE:       09/09/07                 UN NUMBER                            3264

 

PREPARED BY:        ACS Technology       PACKAGING GROUP                                II

 

MANUFACTURER     Hydrite Chemical Co for

ACS Technology

                                5470 Wilson Rd.

                                COS, CO 8099

                                719-265-9141

 

ABBREVIATION KEY: NA= Not Applicable   NE = Not Established   ND = Not Determined

Section 2 – HAZARDOUS INGREDIENTS INFORMATION

 

CHEMICAL INDENTITY                                    HAZARDOUS                                      CAS REG#                                    PERCENTAGES

 

Acidic Calcium Sulfate                                         Yes                                                   NA                                                40 – 60

 

Water                                                                    No                                              7732-18-5                                          40 – 60

 

 

Section 3 – PHYSICAL DATA

 

BOILING POINT: – 104ºC – 105ºC                        SPECIFIC GRAVITY: – (H2O = 1.0) – 1. 28 - 1.30           ODOR: – Odorless and slightly acidic

 

PHYSICAL STATE: - Liquid                                   Appearance – clear to slightly cloudy or opaque       pH: - <1.0

 

FREEZING POINT:  - 5ºC

 

Section 4 – HEALTH HAZARD DATA

 

Exposure to significant quantities of liquid and/or mist may cause irritation or burns to body tissue. Swallowing of large quantities may be fatal.  Harmful if undiluted pHixr I00 is inhaled.  Excessive heat (>100OC)  may cause volatility.  Slightly water reactive.  pHixr 100 Contains strong inorganic acid. 

 

POTENTIAL HEALTH EFFECTS

 

Inhalation:  Inhalation of undiluted pHixr I00 may produces damaging effects on the mucous membranes and upper respiratory tract. Symptoms may include irritation of the nose and throat.  May cause lung edema, a medical emergency.

 

Skin Contact: Corrosive. Symptoms of redness, pain, and burn can occur by skin contact with undiluted pHixr I00.

 

Ingestion: pHixr I00 is a food additive, however ingestion of undiluted pHixr I00 may cause burns to the mouth, throat, and stomach.

 

Eye Contact: Contact with undiluted pHixr I00 may cause blurred vision, redness, pain & severe tissue burns. 

 

 

Aggravation of Pre-existing Conditions: Persons with pre-existing skin disorders or eye problems or impaired respiratory function may be more susceptible to the effects of undiluted pHixr I00.

 

 

Section 5 – FIRST AID MEASURES

 

Inhalation:  Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention immediately.

 

Skin Contact: In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes.  Wash clothing before reuse.

 

Ingestion: If swallowed, DO NOT INDUCE VOMITNG. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

 

Eye Contact: Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.

 

Section 6 – FIRE FIGHTING MEASURES

 

Fire: Concentrated material is a strong dehydrating agent. Do not store around unapproved chemicals (see Section 10). 

 

Explosion: A mild exothermic reaction may occur when undiluted pHixr I00 is added to water. 

 

ACS TECHNOLOGY                                                       Page I of 3                                    MSDS I4076-H – pHixr I00

Fire Extinguishing Media: Dry chemical, foam or carbon dioxide.  Water spray may be used to keep fire exposed containers cool.

 

Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. Structural firefighter's clothing is ineffective for fires involving this material. Stay away from sealed containers.

 

Section 7 – ACCIDENTAL RELEASE MEASURES

 

 

Ventilate area of leak or spill. Wear appropriate personal protective equipment. Isolate hazard area. Keep unnecessary and unprotected personnel from entering. Contain and recover liquid when possible. Neutralize with alkaline material (soda ash, lime), then absorb with an inert material (e.g., vermiculite, dry sand, earth), and place in a chemical waste container. Do not use combustible materials, such as saw dust. Do not flush to sewer. US regulations (CERCLA) require reporting spills and releases to soil, water, and air in excess of reportable quantities. The toll free number for the US Coast Guard National Response Center is 800-424-8802.

 

Section 8 – HANDLING AND STORAGE

 

Store  in well ventilated storage area.  Protect from physical damage. Keep  away from incompatible materials. When diluting, always add pHixr I00 to water; never add water to undiluted pHixr I00.  

 

Section 9 – EXPOSURE CONTROLS / PERSONAL PROTECTION

 

Airborne Exposure Limits:

For  undiluted pHixr I00.

-OSHA Permissible Exposure Unit (PEL): 1mg/m3 (TWA)

-ACGIH Threshold Unit Value (TLV): 1 mg/m3 (TWA), 3 mg/m3 (STEL),  A2 - suspected human carcinogen for undiluted pHixr I00 contained in strong inorganic acid mists.

 

Skin Protection: Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.

 

Eye Protection: Use chemical safety goggles and/or a full face shield where splashing is possible. Maintain eye wash fountain and quick-drench

facilities in work area.

 

Section 10 – STABILITY AND REACTIVITY

 

Stability: Stable under ordinary conditions of use and storage.

 

Hazardous Decomposition Products: Reacts with carbonates to generate carbon dioxide gas, and with cyanides and sulfides to form poisonous hydrogen cyanide and hydrogen sulfide respectively.

 

Hazardous Polymerization: Will not occur.

 

Incompatibilities: Potassium chlorate, potassium perchlorate, potassium permanganate, sodium, lithium, bases, organic material, halogens, metal acetyl ides, oxides and hydrides, metals (yields hydrogen gas), strong oxidizing and reducing agents and many other reactive substances.

 

Conditions to Avoid:  Excessive Heat (>100OC) and incompatibles.

 

Section 11 – TOXICOLOGICAL INFORMATION

 

Toxicological Data: Oral rat LD50: 2140 mg/kg; inhalation rat LC50: 510 mg/m3/2H; standard Draize, eye rabbit, 250 µg (severe); investigated as a tumorigen, mutagen, reproductive effector (0.1N solution).

 

Carcinogenicity: Cancer Status: The International Agency for Research on Cancer (IARC) has classified "strong inorganic acid mists" as a known human carcinogen, (IARC category 1).

 

Section 12 – ECOLOGICAL INFORMATION

 

Environmental Fate: When released into the soil, this undiluted pHixr I00  may leach into groundwater. When released into the air, this material may be removed from the atmosphere to a moderate extent by wet deposition. When released into the air, this material may be removed from the atmosphere to a moderate extent by dry deposition.

Environmental Toxicity: This undiluted pHixr I00 may be toxic to aquatic life.

 

Section 13 – DISPOSAL CONSIDERATIONS

 

Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3. Additionally, waste generators must consult state and local hazardous waste regulations to ensure complete and accurate classification.

RCRA P-Series: None listed.

RCRA U-Series: None listed.

 

Section 14 – TRANSPORTATION

 

Shipping Name:                      Corrosive liquid, Acidic, Inorganic, N.O.S (ACIDIC CALCIUM SULFATE)

Hazard Class:                          8

UN Number:                            UN3264

Packing Group:                      II

 

ACS TECHNOLOGY                                                       Page 2 of 3                                   MSDS I4076-H – pHixr I00

Section 15 – REGULATORY INFORMATION

 

TSCA

CAS# 7664-93-9 is listed on the TSCA inventory.

Health & Safety Reporting List

None of the chemicals are on the Health & Safety Reporting List.

Chemical Test Rules

None of the chemicals in this product are under a Chemical Test Rule.

Section 12b

None of the chemicals are listed under TSCA Section 12b.

TSCA Significant New Use Rule

None of the chemicals in this material have a SNUR under TSCA.

 

SARA

Section 313

pHixr I00 may contain sulfuric acid (CAS# 7664-93-9, 95 98 0%), which is subject to the reporting requirements of Section 313 of SARA Title III and 40 CFR Part 373.

Clean Air Act:

This material does not contain any hazardous air pollutants. This material does not contain any Class 1 Ozone depletors. This material does not contain any Class 2 Ozone depletors.

Clean Water Act:

CAS# 7664-93-9 is listed as a Hazardous Substance under the CWA. None of the chemicals in this product are listed as Priority Pollutants under the CWA. None of the chemicals in this product are listed as Toxic Pollutants under the CWA.

OSHA:

None of the chemicals in this product are considered highly hazardous by OSHA.

STATE

CAS# 7664-93-9 can be found on the following state right to know lists: California, New Jersey, Florida, Pennsylvania, Minnesota, and Massachusetts.

California No Significant Risk Level: None of the chemicals in this product are listed. European/International Regulations

European Labeling in Accordance with EC Directives

Hazard Symbols:

C

 

Section 16 – ADDITIONAL INFORMATION

 

MSDS Creation Date: 6/20/2005

Revision #3 Date: 6/20/2006

The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall ACS Technology be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if ASC Technology has been advised of the possibility of such damages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACS TECHNOLOGY                                                       Page 3 of 3                                   MSDS I4076-H – pHixr I00

































Click Here to find out about our other great “ACS” based products and applications at: ACS Technology, About Us, FreshFlo, pHixr, FDA, AFT,PFT,RTE,FSIS,Studies, Patents, Contact Info, Salmonella Treatment, Pet Food Recalls,Deck cleaners, acidified calcium sulfate, acidic calcium sulfate, ACS 100, Pathogen Control, Animal Drinking Water, Processing Water Treatment, Product Recalls, Safe Pet Food, RTE Meats, Poultry Litter Treatment, ACS, Main site,FreshFlo100 MSDSACSTechnolgy.info, Poultry Nipple Drinker Line Cleaner,